Summary and troubleshooting process suggestions
Troubleshooting steps, specific operation notes, and risks
1. Initial processing, completely power off and restart
2. Visually inspect the grating ruler and cable
3. Clean the Y-axis grating ruler and reading head
4. Check the gap between the reading heads
5. Execute Y-axis reference point operation
6. Use the interchange method to locate faulty components
7. Component replacement in sequence: Reading head ->Motor ->Driver ->Linear ruler